Aspect façade system combines unrivalled aesthetics with increased thermal efficiency, thanks to a superior eClips support system and patented insulation-fix technology.
Aspect’s CTH system (horizontal) is more commonly used for steel frame systems (SFS), where there is likely to be more tolerance in setting out the sub-frame. It is more suited to landscape panels but can also be used for portrait panels.
An all-in-one solution.
Maple are one of the only UK rainscreen cladding installers who own the patent for their system, this means contractors and clients can mitigate risks with an all-in-one solution (One designer, One manufacturer and One Installer).
key features
• For horizontally orientated or square cassette panels• Flexible design accommodates tolerance challenges in fixing zone
• Hidden-fix panels
• Clean, continuous joint lines
ASPECT CTH STIFFENER DATA
Panel face width | Panel face height | Vertical stiffener | Horizontal stiffener | Panel type |
Up to 750mm | Up to 750mm | N | N | CTH |
Up to 750mm | 750mm-1,500mm | N | Y - 1 Stiffener | CTH |
Up to 750mm | 1,500mm-2,250mm | N | Y - 2 Stiffeners | CTH |
Up to 750mm | 2,250mm-3,000mm | N | Y - 3 Stiffeners | CTH |
750mm-1,500mm | Up to 750mm | N | N | CTH |
750mm-1,500mm | 750mm-1,500mm | N | Y - 1 Stiffener | CTH |
750mm-1,500mm | 1,500mm-2,250mm | N | Y - 2 Stiffeners | CTH |
750mm-1,500mm | 2,250mm-3,000mm | N | Y - 3 Stiffeners | CTH |
1,500mm-2,250mm | Up to 750mm | Y - 1 Stiffener | N | CTH |
1,500mm-2,250mm | 750mm-1,500mm | Y - 1 Stiffener | Y - 1 Stiffener | CTH |
NBS SPECIFICATION DATA
MAPLE ARE NOW APPROVED SPECIFICATION NBS CHORUS WRITING PARTNERS
You can specify Aspect® rainscreen façade system using NBS Source. Need help writing your specification? Get in touch with a rainscreen cladding specialist today.